How to perform a calculation with implicit solvent

https://wiki.storion.ru/_media/tut/solvation_models.png?w=120&h=120&tok=92b5e3

Implicit solvation model can be added to your calculation by using VASPsol tool for VASP. There you can find instructions how to compile VASP with the tool and a couple of example how to use it.

VASPsol calculation includes the following steps:

  • Do a vacuum calculation for your system first and save the wavefunction file WAVECAR by specifying LWAVE = .TRUE. in the INCAR file.
  • Start the solvation calculation from the vacuum WAVECAR, specify ISTART = 1 in the INCAR file.
  • The solvation parameters are read from the INCAR file.
    1. LSOL = .TRUE. # switch on the mode for implicit solvent
    2. EB_k = N # relative permittivity of a solvent. Default value is 78.4 for water
    3. Additional parameters:
      1. LRHOB = .TRUE. # writes the bound charge density in the CHGCAR format into RHOB file
      2. LAMBDA_D_K # the Debye length in Angstroms for using the linearized Poisson-Boltzmann model(electrolyte model)
      3. TAU # surface tension parameter

VASP settings for successful calculations:

  • ENCUT parameter should be high enough: 600 eV (for transition metal oxides) or more. PREC = .Accurate.
  • Use the all-electron potentials for H, He, Li and Be
 !------------------------------------------------------------------------
 WARNING: 
 Use all-electron pseudopotential or set CORE_C explicitly 
 for atomic-species with atomic number less than or equal to 4.
 Problem species ATOMIC NUMBER, SYMBOL & VALENCE :           3 Li
   1.00000000000000     
 I HOPE YOU KNOW WHAT YOU ARE DOING !
 !------------------------------------------------------------------------
  • NSW = None
  • LDIPOL = .FALSE.