How to perform a calculation with implicit solvent
https://wiki.storion.ru/_media/tut/solvation_models.png?w=120&h=120&tok=92b5e3
Implicit solvation model can be added to your calculation by using VASPsol tool for VASP. There you can find instructions how to compile VASP with the tool and a couple of example how to use it.
VASPsol calculation includes the following steps:
- Do a vacuum calculation for your system first and save the wavefunction file WAVECAR by specifying LWAVE = .TRUE. in the INCAR file.
- Start the solvation calculation from the vacuum WAVECAR, specify ISTART = 1 in the INCAR file.
- The solvation parameters are read from the INCAR file.
- LSOL = .TRUE. # switch on the mode for implicit solvent
- EB_k = N # relative permittivity of a solvent. Default value is 78.4 for water
- Additional parameters:
- LRHOB = .TRUE. # writes the bound charge density in the CHGCAR format into RHOB file
- LAMBDA_D_K # the Debye length in Angstroms for using the linearized Poisson-Boltzmann model(electrolyte model)
- TAU # surface tension parameter
VASP settings for successful calculations:
- ENCUT parameter should be high enough: 600 eV (for transition metal oxides) or more. PREC = .Accurate.
- Use the all-electron potentials for H, He, Li and Be
!------------------------------------------------------------------------ WARNING: Use all-electron pseudopotential or set CORE_C explicitly for atomic-species with atomic number less than or equal to 4. Problem species ATOMIC NUMBER, SYMBOL & VALENCE : 3 Li 1.00000000000000 I HOPE YOU KNOW WHAT YOU ARE DOING ! !------------------------------------------------------------------------
- NSW = None
- LDIPOL = .FALSE.